Attaching Timber to Concrete
How do you seal timber or a shed wall channel to concrete so water can't get under it?
Use a neutral cure silicone — we nominate Selleys Brick & Concrete Silicone or Selleys Roof & Gutter Silicone for this job. And the key point in our answer is that you probably do not need the timber strip at all. As long as the metal channel and the concrete are clean and dry, the sealant on its own should be sufficient, provided it is applied so it forms a good seal along the entire gap between the ground and the base of the channel.
That is the part worth dwelling on. A shed leaks under its wall channel because water tracks along a continuous capillary gap. A seal that is 95% complete leaks almost as much as no seal at all, because the water simply finds the 5%. The failure is almost never the sealant's flexibility or adhesion — it is a skipped 200 mm behind a downpipe or at a corner.
Why a neutral cure silicone for this joint
You are bonding a coated steel channel on one side to a concrete slab on the other. Both are on the published substrate list for Brick & Concrete Silicone, which is suitable for materials such as bricks and mortar, fibre cement, metal, ceramics, porcelain, concrete, marble and stone, wood, and plastics including polystyrene. Its neutral, non-corrosive formula is the point on a steel channel — an acetic cure product releases acetic acid as it sets, and that is not what you want in permanent contact with metal.
Roof & Gutter Silicone is the alternative, also neutral cure, with a substrate list that includes concrete, masonry, bricks, aluminium, steel and stainless steel, mild and galvanised steel and powder-coated steel. It is available Colorbond colour matched, which is the practical reason to choose it if the shed is a Colorbond one and the bead will be visible from outside.
Limitations you need to respect
- Do not use Brick & Concrete Silicone in below ground applications, and not in below waterline applications either. It is for the joint at ground level, not for anything buried.
- Roof & Gutter Silicone is not recommended for continuous submersion or below-waterline use. If your slab ponds water against the wall after rain, fix the drainage — no sealant is the answer to standing water.
- Neither is paintable. Complete any painting 7 days before applying the sealant.
- Not for polyethylene, polypropylene or PTFE in either case. Pre-test any plastics.
- Roof & Gutter application limits: do not apply if the ambient or substrate temperature is below +5 °C or above +40 °C, and avoid contact with high-plasticiser materials such as rubber and bituminous substrates.
- Brick & Concrete application temperature is −40 °C to 140 °C for service; clean, dry preparation is required regardless of weather.
Preparation, which is where this job is won
- Clear the gap. Remove any old sealant, dirt, loose concrete and rust scale. Anything crumbling will come away later and take the bead with it.
- Clean and dry both faces. Thoroughly clean and dry the surfaces of oil, dirt and grease with mineral turps. Concrete that looks dry can still be damp — leave it a warm day after any rain.
- Cut the tip off the cartridge and cut the nozzle at a 45 degree angle, sized to the gap. Fit the nozzle and load the caulking gun.
- Extrude a little onto scrap first to get a smooth continuous flow before you start on the shed.
- Hold the gun at 45 degrees and gun the sealant ahead of the nozzle, pushing the product into the joint rather than smearing it across the surface. Work along the full perimeter without leaving gaps — including behind downpipes, at corners and where the channel steps over any slab variation.
- Tool with a spatula dipped in soapy water, or in mineral turps, for a smooth finish that sheds water rather than holding it.
- Clean up before the sealant skins with a cloth dampened in mineral turps.
- Leave it 72 hours. After that, any surplus can be trimmed with a sharp blade — but avoid undercutting the seal.
The two products side by side
| Property | Brick & Concrete Silicone | Roof & Gutter Silicone |
|---|---|---|
| Technology | Neutral cure silicone (oxime) | Neutral cure, 100% silicone, moisture curing |
| Colour / pack | Grey, 415 g cartridge | Colorbond matched range and translucent, mostly 300–310 g |
| Tooling time | 35 minutes | 5 minutes |
| Skin time | 70 minutes | 5–10 minutes |
| Tack-free time | 90 minutes | 30 minutes |
| Cure rate | 2 mm / 24 hours (cures in 72 hours) | 2 mm / 24 hours |
| Movement capability | ±50% (ISO 9047 Method B) | ±25% |
| Elongation at break | 960% (ASTM D412) | 330% (ASTM D412) |
| Shore A hardness | 16 | 32 |
| Tensile strength | 1.2 MPa (ASTM D412) | — |
| Elastic recovery | 89% (ISO 7389 Method B, 100%) | — |
| Service temperature | −40 °C to 140 °C | −60 °C to +150 °C |
| Standard | ISO 11600 Type F Class 25LM | — |
Indicative data only, not intended for the preparation of specifications.
What those numbers mean for a shed base
Movement capability is why Brick & Concrete is the better default here. Its ±50% figure and 960% elongation describe a soft, very extensible seal. A shed wall on a slab moves — thermal expansion along a long steel run in the sun is real, and the slab and the shed do not move together. A joint sealed with a low-modulus product absorbs that; a stiff bead transfers the load to the bond line and eventually peels.
Tooling and skin times set your working rhythm. Brick & Concrete gives you 35 minutes of tooling time and 70 minutes before it skins, which is generous — you can run a long wall and come back to smooth it. Roof & Gutter gives you 5 minutes of tooling and skins in 5–10, so with that product you must work in short sections and tool each one as you go. On a job whose whole point is a continuous unbroken bead, the longer working time is a genuine advantage.
The 2 mm per 24 hours cure rate means depth costs time. A bead pushed properly into a 6 mm gap is still curing three days later at its core. Do not hose the shed down or expect a rain event to be a fair test for at least that long.
Joint size, if you are using Roof & Gutter
Its technical data sheet gives a joint design guide: minimum joint width and depth of 5 mm, an optimum width-to-depth ratio of 2:1, a 1:1 ratio for widths up to 12 mm, and 2:1 for widths greater than 12 mm. For joints deeper than the ratio allows, use a backer rod 25–50% larger than the joint width.
Related questions and guides
Related pages, and others in this section:
- How To Fill Gaps and Seal a Shed to a Concrete Slab
- How To Seal an Exterior Gap in Concrete
- Assessing a hairline crack in a pebblecrete pool
- Best Sealant for Caravan Joints
- Best Sealant for Cracked or Broken Roof Tiles
- Best Sealant for the Base of a Garden Shed
- Best Sealant To Seal Plexiglass to Aluminium
- Can a hair dryer speed up Wet Area Silicone curing?
Browse from here
Where this page sits:
Do I need to add a timber strip?
We cannot establish that from the question. Confirm the channel and drainage detail with the shed installer before adding timber.
How do you seal timber or a shed wall channel to concrete so water can't get under it?
Use a neutral cure silicone — we nominate Selleys Brick & Concrete Silicone or Selleys Roof & Gutter Silicone for this job. And the key point in our answer is that you probably do not need the timber strip at all . As long as the metal channel and the concrete are clean and dry, the sealant on its own should be sufficient, provided it is applied so it forms a good seal along the entire gap between the ground and the base of the channel.
Why a neutral cure silicone for this joint?
You are bonding a coated steel channel on one side to a concrete slab on the other. Both are on the published substrate list for Brick & Concrete Silicone, which is suitable for materials such as bricks and mortar, fibre cement, metal, ceramics, porcelain, concrete, marble and stone, wood, and plastics including polystyrene.
What should I know about limitations you need to respect?
Do not use Brick & Concrete Silicone in below ground applications , and not in below waterline applications either. It is for the joint at ground level, not for anything buried; Roof & Gutter Silicone is not recommended for continuous submersion or below-waterline use. If your slab ponds water against the wall after rain, fix the drainage — no sealant is the answer to standing water; Neither is paintable. Complete any painting 7 days before applying the sealant; Not for polyethylene, polypropylene or PTFE in either case. Pre-test any plastics.
What should I know about preparation, which is where this job is won?
Clear the gap. Remove any old sealant, dirt, loose concrete and rust scale. Anything crumbling will come away later and take the bead with it; Clean and dry both faces. Thoroughly clean and dry the surfaces of oil, dirt and grease with mineral turps. Concrete that looks dry can still be damp — leave it a warm day after any rain; Cut the tip off the cartridge and cut the nozzle at a 45 degree angle , sized to the gap. Fit the nozzle and load the caulking gun; Extrude a little onto scrap first to get a smooth continuous flow before you start on the shed.
What those numbers mean for a shed base?
Movement capability is why Brick & Concrete is the better default here. Its ±50% figure and 960% elongation describe a soft, very extensible seal. A shed wall on a slab moves — thermal expansion along a long steel run in the sun is real, and the slab and the shed do not move together.
What should I know about joint size, if you are using Roof & Gutter?
Its technical data sheet gives a joint design guide: minimum joint width and depth of 5 mm, an optimum width-to-depth ratio of 2:1, a 1:1 ratio for widths up to 12 mm, and 2:1 for widths greater than 12 mm. For joints deeper than the ratio allows, use a backer rod 25–50% larger than the joint width.
What problem is being addressed on this Selleys 'Ask an Expert' page?
The page addresses how to seal timber to concrete so that water does not leak between the two surfaces, specifically in the context of garden sheds. As long as the metal channel and the concrete are clean and dry, the sealant on its own should be sufficient, provided it is applied so it forms a good seal along the entire gap between the ground and the base of the channel.