Pack, technology and materials
TechnologyHybrid Polymer
ColourClear

Undo Glue Gel: technical details

Technical data · page 1
Product and Technical Information
Product DataTechnical Performance
TechnologyHybrid PolymerSkin Time30-60 minutes
Cure MechanismMoisture curingCuring RateApprox. 4mm/24hrs
Specific Gravity1.03Shore A Hardness34
ColourClearApplication Temperature+5 °C to +40 °C
Shelf life12 monthsService Temperature-20 °C to +70 °C
Storage Temperature+5 °C to +25 °C
The table results are based on current product material data, quality test methods, and testing conditions, such as temperature, moisture, and substrate.
Technical data · page 2
Load Capacity
Estimate load capacity over time for each hook size type
TimeSmallMediumLarge
Instant10 g30 g60 g
1 hour100 g200 g400 g
2 hours300 g400 g500 g
24 hours2 kg3 kg5 kg
Technical data · page 2
Coverage and Consumption
Estimate quantity of hook size types and packaging sizes to which the product can be applied.
Hook Size
Adhesive Packaging SizeSmallMediumLarge
5 g1271
10 g24103
Technical data · page 3
SizeAvailable Pack
Undo Glue
Undo Glue
Undo Glue 5g + S 4pk Hook
Undo Glue 5g + M 4pk Hook
Undo Glue 10g + S 10pk Hook
Undo Glue 10g + M 10pk Hook
Undo Glue 5g + L 2pk Hook
Undo glue 5g + S 3pk Hook
Undo Glue 5g + M 3pk Hook
5 g
10 g
5 g + S hook
5 g + M hook
10 g + S hook
10 g + M hook
5 g + L hook
5 g + S hook
5 g + M hook

What it does

  • Strong hold
  • Easy removal
  • No damage upon removal
  • Adheres to a wide variety of substrates
  • Non-flammable
  • Low odour and VOC

Conditions for these figures

As a guide, to facilitate clean removal, allow the adhesive to fully cure prior to removal. Under typical conditions, the product may remain adhered to porous substrates for up to 3 days and to non-porous substrates for up to 5 days before removal. For any remaining adhesive on textured surfaces, we recommend using Selleys Sealant Remover for easy clean-up.

Conditions and compatibility

  • Not for use on polyethylene, polypropylene or PTFE (Teflon®).
  • Pre-test compatibility with substrates before use.
  • Do not apply if the ambient or substrate surface temperature is below +5 °C or above +40 °C. Optimal application temperature is between +5 °C and +25 °C.
  • At low temperatures, curing speed slows.
  • Not suitable for extremely aged or compromised walls.
  • The product may leave a stain on porous surfaces.
  • Wait a minimum of 28 days after painting to apply.
  • Mechanically fix valuable items.
  • For optimal performance, remove and re-apply glue every 2 years.
  • Selleys® recommends users conduct their own risk assessment before use to determine the product's suitability. A sample should be applied to the intended area to ensure acceptable appearance, finish, and performance on the substrate.

Technical data sheet ·

Choose a sound surface

Undo Glue is a removable adhesive for lightweight mounting, including Selleys hooks. Clean away dust, oil, rust and other contamination, and pre-test the intended surface. It is not suitable for polyethylene, polypropylene, PTFE or very aged or compromised walls.

Wait at least 28 days after painting. Porous surfaces may stain; mechanically fix valuable items.

Source: Technical data sheet, page 1.

Apply and allow to cure

For Selleys hooks, apply along the marked lines on the back, using an amount suitable for the hook size. Position and press evenly for about 30 seconds. Allow full cure before loading.

For lightweight mountable items, use adhesive dots about 10–15 mm across, positioned about 30 mm from the edges: two for A4 or smaller, four for A3, and six for A2. Press evenly for about 30 seconds and allow full cure before use.

Source: Technical data sheet, page 2.

Hook size and load

The TDS gives estimated load capacities at 24 hours of 2 kg for a small hook, 3 kg for a medium hook and 5 kg for a large hook. These are estimates for the specified hook sizes, not an immediate loading allowance or a rating for every mounted object. Follow the instruction to let the adhesive cure fully before applying a load.

Source: Technical data sheet, page 2.

Remove by twisting

Grip the edges and twist firmly anticlockwise. Do not pull the item towards you: that can damage the surface. Allow full cure before removal, then peel away residue and clean as needed. Follow the complete removal notes in the TDS for your surface; it recommends Selleys Sealant Remover for residue on textured surfaces.

Source: Technical data sheet, page 2.

Temperature, maintenance and storage

Apply only when the air and surface are between 5°C and 40°C; the optimum application range is 5–25°C. Low temperatures slow cure. The TDS recommends removing and reapplying the glue every two years for optimal performance.

Store unopened packaging below 25°C in a cool, dry place away from direct sunlight. Best used within 12 months of manufacture.

Source: Technical data sheet, page 3.

Safety before you start

Check the product name on your pack against the Australian SDS below before use.

SELLEYS UNDO GLUE

SDS signal word: Warning.

Handling: Avoid eye contact and skin contact. Avoid inhalation of dust.

Protective equipment and ventilation

Wear safety shoes, overalls, gloves, safety glasses. Available information suggests that gloves made from nitrile rubber should be suitable for intermittent contact. However, due to variations in glove construction and local conditions, the user should make a final assessment. Always wash hands before smoking, eating, drinking or using the toilet. Wash contaminated clothing and other protective equipment before storing or re-using.

Ventilation: Natural ventilation should be adequate under normal use conditions.

Australian safety data sheet · issued 29 January 2026 · sections 2, 7 and 8. Read the full SDS for first aid, spill response, incompatibilities and disposal.

SELLEYS UNDO GLUE: storage and product data

Store between jobs

Store in a cool, dry, well-ventilated place and out of direct sunlight. Store away from foodstuffs. Store away from incompatible materials described in Section 10. Store away from sources of heat and/or ignition. Keep container standing upright. Keep containers closed when not in use - check regularly for spills.

Typical physical properties from this SDS
FormPaste
ColourClear
OdourCharacteristic
SolubilityInsoluble in water
Specific Gravity1.03
Relative Vapour Density (air=1)>1
Vapour PressureN App
Flash Point (°C)N App
Explosion/Flammability LimitsN App
Autoignition Temperature (°C)N Av
Melting/Freezing Point/Range (°C)N Av
Boiling Point/Range (°C)N Av
pHN App
ViscosityN Av
Total VOC (g/Litre)N Av

Others in this range

Alongside this product:

Browse from here

Where this page sits:

Elsewhere in this category

Nearby products and groups:

Typical values describe the material in this safety data sheet. They are not application instructions or performance guarantees. N Av means not available; N App means not applicable.

Ingredients disclosed in the SDS
CHEMICAL ENTITY CAS NO PROPORTION
Trimethoxyvinylsilane 2768-02-7 1 - 10 % (w/w)
Ingredients determined to be non-hazardous or below reporting limits Balance
____________
100%

These are the ingredients disclosed for hazard communication, not the complete formulation. Use the application instructions to decide suitability for your project.

First aid from the matching SDS

If poisoning occurs, contact a doctor or Poisons Information Centre (Phone Australia 131 126, New Zealand 0800 764 766).

Inhalation: Remove victim from exposure - avoid becoming a casualty. Remove contaminated clothing and loosen remaining clothing. Allow patient to assume most comfortable position and keep warm. Keep at rest until fully recovered. Seek medical advice if effects persist.

Skin Contact: Effects may be delayed. If skin or hair contact occurs, remove contaminated clothing and flush skin and hair with running water. If swelling, redness, blistering or irritation occurs seek medical assistance. Eye Contact: If in eyes wash out immediately with water. In all cases of eye contamination it is a sensible precaution to seek medical advice.

Ingestion: Rinse mouth with water. If swallowed, do NOT induce vomiting. Give a glass of water to drink. Never give anything by the mouth to an unconscious patient. If vomiting occurs give further water. Seek medical advice.

PPE for First Aiders: Wear safety shoes, overalls, gloves, safety glasses. Available information suggests that gloves made from nitrile rubber should be suitable for intermittent contact. However, due to variations in glove construction and local conditions, the user should make a final assessment. Always wash hands before smoking, eating, drinking or using the toilet. Wash contaminated clothing and other protective equipment before storing or re-using. Notes to Physician: Treat symptomatically. Effects may be delayed.

Disposal

Persons conducting disposal, recycling or reclamation activities should ensure that appropriate personal protection equipment is used, see "Section 8. Exposure Controls and Personal Protection" of this SDS. If possible material and its container should be recycled. If material or container cannot be recycled, dispose in accordance with local, regional, national and international Regulations.

Australian SDS · sections 1, 3, 4, 7, 9 and 13 · 29 January 2026

Technical and safety documents

The technical data sheet covers application and performance conditions. The safety data sheet covers hazards and safe handling. Use both alongside the pack instructions.

Need a hand choosing the right document or checking your application? Contact our team with the product name, pack code, surfaces and intended use.

What can I mount with Undo Glue?

Use it with Selleys Undo Hooks or for suitable lightweight posters, photo frames, decorations, crafts, temporary assembly and toilet-roll, soap or towel holders. Test the surface first and mechanically fix valuable items.

Can it damage or stain a wall?

Clean removal depends on a suitable surface and following the directions. Do not use on extremely aged or compromised walls. Porous surfaces may stain; pre-test appearance and performance, and never pull the mounted item towards you.

How long after painting should I wait?

Wait at least 28 days before applying Undo Glue, and pre-test the surface.

Can I use it on PE, PP or PTFE?

No. Do not use on polyethylene, polypropylene or PTFE (Teflon).

How do I apply glue to a hook?

Apply along the marked lines on the back, using an amount suitable for the hook size. Position and press firmly and evenly for about 30 seconds. Allow full cure before applying any load.

How much weight can the hooks hold?

The technical sheet estimates 2 kg for small, 3 kg for medium and 5 kg for large hooks at 24 hours, when used as directed. Allow full cure before loading; low temperatures slow cure. These are hook ratings, not ratings for all directly mounted items.

How much glue do I use without a hook?

Use dots about 10–15 mm across, around 30 mm from the edges: two for A4 or smaller, four for A3, six for A2. Press firmly and evenly for about 30 seconds and allow full cure.

Can I load a hook immediately using the table’s instant rating?

Follow the application instruction: allow full cure before any load. The early-time figures are estimated reference data, not permission to load early.

How do I remove a hook?

After full cure, grip the edges and twist firmly anticlockwise. Never pull towards you. Peel residue from both surfaces and clean as needed; our technical sheet recommends Selleys Sealant Remover for residue on textured surfaces.

Can I leave it mounted for years?

The sheet recommends removing and reapplying every 2 years, but its removal note also refers to up to 3 days on porous surfaces and 5 days on non-porous surfaces before removal. Ask our team how that note applies to your surface and intended duration before relying on long-term removable mounting.

Can I reuse the glue?

No. Our online FAQ says the adhesive is single use. Reuse the hook with fresh Undo Glue.

Can I use it on damp surfaces?

The technical sheet allows dry or damp surfaces; our online key information requires clean, dry surfaces. Check the exact pack or ask our team before damp-surface use.

How do I store an unopened tube?

Store below 25 °C in a cool, dry place out of direct sunlight and use within 12 months of manufacture. The technical table gives +5 to +25 °C. Keep containers upright and closed, away from food, oxidisers, heat and ignition sources.

Is it hazardous?

Yes. The safety sheet warns that it may cause an allergic skin reaction and requires protective equipment. It is not classified as dangerous goods for transport, but this does not remove its handling or fire precautions.