Selleys ProSeries Acryseal is an acrylic fire and acoustic rated sealant for perimeter and penetration seals in fire rated construction.

VariantPriceAvailability
SelleysProSeriesAcryseal

Selleys Fireblock AC

An intumescent acrylic sealant for internal, non-trafficable control joints in concrete, masonry and brick fire-rated construction, with penetration and perimeter sealing in plasterboard and acoustic sealing.

Check the pack details below, then find a retailer near you. Range and availability vary by store.

Selleys Fireblock AC — product image

Product details

Pack, technology and materials
ColourLight grey

Selleys Fireblock AC: technical details

Technical data · page 1
PropertyTypical Result
TechnologyWater based Acrylic
ColourGrey
DensityApprox. 1.58
Application
Temperature
10°C - 35°C
Skin Time30 mins approx.
23°C / 50% RH
Elongation at break
(ASTM D412)
800% approx.
Tensile Strength0.28 MPa approx.
(ASTM D412)
Movement Capability
(ISO 9046)
+/- 25%
Fire Rating
(AS1530.4-2014)
Up to 4 hrs
Acoustic Rating>60 Rw
Indicative data only, not intended for preparation of specifications
Technical data · page 1
PackagingSizeColour
Sausage600mlGrey

Technical data sheet · 17/07/2025

Choose the right Fireblock and tested system

An intumescent acrylic sealant for internal, non-trafficable control joints in concrete, masonry and brick fire-rated construction, with penetration and perimeter sealing in plasterboard and acoustic sealing.

Before application, consult the project fire certifier or engineer. The required fire performance depends on the tested construction, substrates, joint geometry and installation. Use the relevant assessment and approved project detail; a fire-rating claim is not a blanket approval for every joint or penetration.

Source: Technical data sheet, page 1.

Prepare and apply

  1. Clean and dry the substrates. Remove oil, grease, release agents, dust and loose material.
  2. Cut the sausage tip, load the caulking gun and fit a nozzle cut to suit the joint.
  3. Install the backing material required by the approved joint detail to control depth and avoid adhesion to the back of the joint.
  4. Extrude smoothly so the sealant wets both joint faces fully.
  5. The TDS application section specifies joint widths of 10–40 mm for fire-rated work, with a minimum depth of 10 mm, or half the width for joints wider than 20 mm. Confirm these dimensions against the tested system and the project requirements before installation.

Source: Technical data sheet, page 1.

Painting and application limits

Let a thick skin form before applying a flexible paint. Allow full cure before using flat or ceiling paint to reduce the risk of cracking.

Use AC for the internal applications described above. Its directions say exterior applications are not recommended, although a later general limitation mentions exterior protection. Obtain written confirmation from our team before specifying AC outside.

Do not use for continuous submersion or below-waterline applications.

Source: Technical data sheet, page 2.

Cleanup, storage and shelf life

Clean spills and tools with water before cure. Cured sealant on tools needs soaking in water followed by mechanical removal.

Store below 28°C and not below 0°C. The TDS states a shelf life of 24 months from manufacture.

Source: Technical data sheet, page 2.

Safety before you start

Check the product name on your pack against the Australian SDS below before use.

FIREBLOCK AC

SDS signal word: Warning.

Handling: Avoid eye contact and skin contact. Avoid inhalation of dust.

Protective equipment and ventilation

Wear safety shoes, overalls, gloves, safety glasses. Available information suggests that gloves made from nitrile rubber should be suitable for intermittent contact. However, due to variations in glove construction and local conditions, the user should make a final assessment. Always wash hands before smoking, eating, drinking or using the toilet. Wash contaminated clothing and other protective equipment before storing or re-using.

Ventilation: Natural ventilation should be adequate under normal use conditions.

Australian safety data sheet · issued 24 April 2024 · sections 2, 7 and 8. Read the full SDS for first aid, spill response, incompatibilities and disposal.

FIREBLOCK AC: storage and product data

Store between jobs

Store in a cool, dry, well-ventilated place and out of direct sunlight. Store away from foodstuffs. Store away from incompatible materials described in Section 10. Store away from sources of heat and/or ignition. Keep container standing upright. Keep containers closed when not in use - check regularly for spills.

Typical physical properties from this SDS
FormPaste
ColourVarious
OdourCharacteristic
SolubilityDispersible in water
Specific Gravity1.57
Relative Vapour Density (air=1)>1
Vapour PressureN Av
Flash Point (°C)N App
Explosion/Flammability LimitsN App
Autoignition Temperature (°C)N Av
Melting Point/Range (°C)N Av
Boiling Point/Range (°C)N Av
pHN Av
Viscosity>14 mm²/s @ 40 °C
Total VOC (g/Litre)N Av

Others in this range

Alongside this product:

Browse from here

Where this page sits:

Elsewhere in this category

Nearby products and groups:

Typical values describe the material in this safety data sheet. They are not application instructions or performance guarantees. N Av means not available; N App means not applicable.

Ingredients disclosed in the SDS
CHEMICAL ENTITY CAS NO PROPORTION
1,2-Benzisothiazol-3(2H)-one (BIT) 2634-33-5 <0.05 % (w/w)
2-Methyl-2H-isothiazol-3-one (MIT) 2682-20-4 <0.05 % (w/w)
Ingredients determined to be non-hazardous or below reporting limits Balance
____________
100%

These are the ingredients disclosed for hazard communication, not the complete formulation. Use the application instructions to decide suitability for your project.

First aid from the matching SDS

If poisoning occurs, contact a doctor or Poisons Information Centre (Phone Australia 131 126, New Zealand 0800 764 766).

Inhalation: Remove victim from exposure - avoid becoming a casualty. Remove contaminated clothing and loosen remaining clothing. Allow patient to assume most comfortable position and keep warm. Keep at rest until fully recovered. Seek medical advice if effects persist.

Skin Contact: Effects may be delayed. If skin or hair contact occurs, remove contaminated clothing and flush skin and hair with running water. If swelling, redness, blistering or irritation occurs seek medical assistance.

Eye contact: If in eyes wash out immediately with water. In all cases of eye contamination it is a sensible precaution to seek medical advice.

Ingestion: Rinse mouth with water. If swallowed, do NOT induce vomiting. Give a glass of water to drink. Never give anything by the mouth to an unconscious patient. If vomiting occurs give further water. Seek medical advice.

PPE for First Aiders: Wear safety shoes, overalls, gloves, safety glasses. Available information suggests that gloves made from nitrile rubber should be suitable for intermittent contact. However, due to variations in glove construction and local conditions, the user should make a final assessment. Always wash hands before smoking, eating, drinking or using the toilet. Wash contaminated clothing and other protective equipment before storing or re-using.

Notes to physician: Treat symptomatically. Effects may be delayed.

Disposal

Persons conducting disposal, recycling or reclamation activities should ensure that appropriate personal protection equipment is used, see "Section 8. Exposure Controls and Personal Protection" of this SDS. If possible material and its container should be recycled. If material or container cannot be recycled, dispose in accordance with local, regional, national and international Regulations.

Australian SDS · sections 1, 3, 4, 7, 9 and 13 · 24 April 2024

Technical and safety documents

The technical data sheet covers application and performance conditions. The safety data sheet covers hazards and safe handling. Use both alongside the pack instructions.

Need a hand choosing the right document or checking your application? Contact our team with the product name, pack code, surfaces and intended use.

Does Fireblock AC always provide four hours protection?

No. Use the tested construction, joint dimensions and configuration approved by the project fire certifier or engineer.

Can I use it outside?

The TDS explicitly does not recommend exterior application, despite a later exterior-care note. Ask us before proposing that use.

When can I paint?

Wait for a thick skin before flexible paint, and full cure before flat or ceiling paint. No universal full-cure time is given.

Does the acoustic opinion approve every wall?

No. It describes panel-density, sealant-depth and wall-system conditions. Obtain project-specific acoustic advice where performance must be guaranteed.

How do I choose the right Fireblock and tested system?

An intumescent acrylic sealant for internal, non-trafficable control joints in concrete, masonry and brick fire-rated construction, with penetration and perimeter sealing in plasterboard and acoustic sealing. Before application, consult the project fire certifier or engineer. The required fire performance depends on the tested construction, substrates, joint geometry and installation.

How do I prepare and apply?

Clean and dry the substrates. Remove oil, grease, release agents, dust and loose material; Cut the sausage tip, load the caulking gun and fit a nozzle cut to suit the joint; Install the backing material required by the approved joint detail to control depth and avoid adhesion to the back of the joint; Extrude smoothly so the sealant wets both joint faces fully; The TDS application section specifies joint widths of 10–40 mm for fire-rated work, with a minimum depth of 10 mm, or half the width for joints wider than 20 mm. Confirm these dimensions against the tested system and the project requirements before installation.

What should I know about painting and application limits?

Let a thick skin form before applying a flexible paint. Allow full cure before using flat or ceiling paint to reduce the risk of cracking. Use AC for the internal applications described above. Its directions say exterior applications are not recommended, although a later general limitation mentions exterior protection.

What should I know about cleanup, storage and shelf life?

Clean spills and tools with water before cure. Cured sealant on tools needs soaking in water followed by mechanical removal. Store below 28°C and not below 0°C. The TDS states a shelf life of 24 months from manufacture.

What should I know about safety before I start?

Check the product name on your pack against the Australian SDS below before use. Handling: Avoid eye contact and skin contact. Avoid inhalation of dust. Wear safety shoes, overalls, gloves, safety glasses. Available information suggests that gloves made from nitrile rubber should be suitable for intermittent contact.

Which technical and safety documents are available?

The technical data sheet covers application and performance conditions. The safety data sheet covers hazards and safe handling. Use both alongside the pack instructions. Need a hand choosing the right document or checking your application? Contact our team with the product name, pack code, surfaces and intended use.

What should I know about FIREBLOCK AC?

Store in a cool, dry, well-ventilated place and out of direct sunlight. Store away from foodstuffs. Store away from incompatible materials described in Section 10. Store away from sources of heat and/or ignition. Keep container standing upright. Keep containers closed when not in use - check regularly for spills.

What are its physical and chemical properties?

Form: Paste; Colour: Light grey; Odour: Characteristic; pH: N Av; Viscosity: 14 mm²/s @ 40 °C; Specific Gravity: 1.57; Solubility: Dispersible in water; Boiling Point/Range (°C): N Av; Melting Point/Range (°C): N Av; Vapour Pressure: N Av; Relative Vapour Density (air=1): 1.